Q: How does USP <800> refer to closed system transfer devices (CSTDs)?

A: CSTDs are referred to as a containment supplemental engineering control that provide adjunct controls to offer an additional level of protection during compounding or administration. Supplemental engineering controls may also facilitate enhanced occupational protection, especially when handling HDs outside of primary and secondary engineering controls.

Q: Does USP <800> acknowledge that all CSTDs will perform adequately?

A: No, USP <800> reveals that there is no certainty that all CSTDs will perform adequately. Therefore, users should carefully evaluate the performance claims associated with available CSTDs based on independent, peer-reviewed studies and demonstrated contamination reduction.

Q: Can hazardous drugs (HDs) vaporize at room temperature increasing risk of occupational exposure?

A: Yes, the Oncology Nursing Society (ONS) Toolkit for Safe Handling of Hazardous Drugs for Nurses in Oncology identifies 8 HDs with the potential to vaporize at room temperature including Carmustine, Cisplatin, Cyclophosphamide, Etoposide, 5-Florouracil, Ifosfamide, Nitrogen mustard and Thiptepa.

Q: Why does USP <800> indicate that it is important to contain HDs vapors?

A: USP <800> states that a potential opportunity of exposure during administration includes generating aerosols of HDs by various routes (Ex. Injection, irrigation, oral, inhalation or topical administration).

Q: Does USP <800> indicate that a CSTD can help contain HDs vapors when utilized?

A: Yes, USP <800> states that some CSTDs have been shown to limit the potential of generating aerosols during compounding.

Q: Does USP <800> still allow for the use of two tiers of containment (Ex. CSTD within a BSC) that is in a non-negative pressure room for facilities that prepare a low volume of HDs?

A: No, USP <800> states that a CSTD must not be used as a substitute for a containment primary engineering control (C-PEC) which must be in a room with negative pressure between 0.01 and 0.03 inches of water column relative to all adjacent areas.

Q: When does USP <800> indicate that a CSTD should be utilized?

A: USP <800> states that a CSTD should be used when compounding HDS when the dosage form allows. Furthermore, USP <800> states that a CSTD must be used when administering antineoplastic HDs when the dosage form allows.

Q: Do USP standards indicate how affixing a CSTD to a vial impact beyond use dating (BUD)?

A: No, USP <797> revisions and USP <800> do not state that attachment of a CSTD to a medication vial either reduces or prolongs the beyond use date (BUD) of a medication vial (single or multiple dose). Therefore, for medication vials with an attached CSTD, BUD remains unchanged from USP standards. USP, Joint Commission and other regulatory bodies also do not currently endorse the utilization of a CSTD for prolonging the BUD of single dose vials, which is also known as dose vial optimization (DVO) due to patient safety concerns.

Acknowledgement

For state specific information on USP 800, please contact your state’s Board of Pharmacy.

Related Blogs

healthcare worker handling chemotherapy hazardous drug
April 2024
#air-tight
#CSTD
#hazardous drugs
#leak-proof

The Unseen Dangers: Understanding the Occupational Risks of Chemotherapy Drugs and the Protective Role of EQUASHIELD’s CSTD

Mitigating Contamination of Chemotherapy Agents While Compounding with CSTD
March, 2024
#CSTD Preparation
#Head of Pharmacy
#leak-proof

Case Studies: Assessment of CSTDs for Mitigating Contamination of Chemotherapy Agents While Compounding 

Compounding facilities washing hands
March, 2024
#CSTD Preparation
#Head of Pharmacy
#UK

The Impact of Standards on Compounding Pharmacies and Outsourced Facilities 

References